testo 150 DIN2 – two inputs for NTC/Pt100 sensors
Two inputs for sensors with mini-DIN connector
- Can store 128,000 measurements
- Measurement range: -40 ... +150 °C (NTC) or -200 ... +600 °C (PT100)
- 2 inputs for sensors with mini-DIN connectors
Datalogger testo 150 DIN2
The data logger testo 150 DIN2 is part of the measuring system testo Saveris and enables safe, simple and efficient monitoring of critical temperature values in accordance with the strictest GxP regulations. Two temperature sensors with mini-DIN connectors can be connected for monitoring premises, freezers, refrigerators and any place that requires temperature monitoring.
Thanks to the various communication modules (see under the accessories tab), this testo 150 logger can be integrated into any existing network environment (WLAN, LAN). Optional testo UltraRange is also available, which with its wireless radio technology allows the transmission of measured values over long distances.
- Can store 128,000 measurements
- Measurement range: -40 ... +150 °C (NTC) or -200 ... +600 °C (PT100)
- 2 inputs for sensors with mini-DIN connectors
- Can be integrated into any WLAN or LAN network (optional)
- Radio transmission with testo UltraRange (optional)
Briefly about the measurement system
The base station testo Saveris Base V 3.0 is the "heart" of the system. There is also a CFR software that handles all the collection, visualization and documentation of measurement data. The software includes the 'Cockpit' feature that gives you an unprecedented overview of the entire system. In addition to the base station and software, there is also a database, which is installed on your own server.
There are three different types of data loggers to choose from, depending on whether you want to use thermocouple sensors, analog or digital sensors. With the help of an analog converter, many more measurement quantities can be connected, such as e.g. moisture transmitters.
Advantages
- Clear and simple overview: measuring point overview with display of alarms and measured values.
- Easy access: login and sign alarms on your smartphone.
- Measurement data security: the measurement values are stored in three different places, in the base station, in the data loggers and in the database, which is located on your own server.
- Traceability: accredited calibration and audit trail functionality.
- Flexibility: several different measurement quantities °C, %RH, CO2, Pa, level etc.
- Accuracy: fully digital sensors for temperature and relative humidity.
- Borderless communication: combine radio networks, fixed (LAN) and wireless networks (WLAN) in the same measurement system.
We help from start to finish
We assist you all the way with your testo Saveris system. We take care of everything from design to installation, qualification and validation.
Our services
- Accredited field calibration at your premises: when it is time for calibration, we come and perform an accredited field calibration at your premises.
- Mapping: we can provide temperature mapping of your warehouses and premises.
- Validation: after installation and commissioning, we can offer validation of your system.
- Advice: we have extensive experience with everything from large to small measurement systems and are happy to provide any advice you need.
Included in delivery
Data logger testo 150 DIN2, wall bracket, batteries and factory protocol.
The handy Cockpit function visualizes data loggers, sensors and alarms directly in floor plans of your own facility. You get an unprecedented overview of the entire measurement system and can easily see where a limit value has been exceeded.
| Display type | Segment |
| Display functions | Display of 2 measurement channels, exceeded limit values, connection status, signal strength, battery status, display can be disabled |
| Material in instrument housing | PC/PET (front) ABS+PC+10% GF/PET (back) |
| Dimensions (H x W x L) | 69.3 x 87.9 x 29.0 mm |
| Measurement range | NTC: -40 ... +150 °C PT100 (with external sensor): -200 ... +600 °C |
| Accuracy (±1 digit) | NTC: ±0.3 °C Pt100: ±0.1 °C (0 ... +60 °C) ±0.2 °C (-100 ... +200 °C) ±0.5 °C (other measuring range) |
| Resolution | NTC: 0.1°C / 0.1°F Pt100: 0.01 °C / 0.01 °F |
| Weight | About 255 g |
| Protection class | IP 67 & IP 65 (with connected communication module: testo UltraRange and WLAN), IP 30 (Ethernet) (each without sensor) |
| Storage temperature | -40 ... +60 °C |
| Operating temperature | -40 ... +50 °C |
| Power supply | as an option via power supply & micro-USB (0572 5004) |
| Battery type | 4 AA alkaline batteries (manganese) At temperatures below +10 °C batteries of type Energizer LI (0515 0572) are recommended |
| Battery life | testo UltraRange: up to 6.5 years WLAN: 3 years (1 hour transmission interval, 15 min measurement interval, +25 °C, 1 analog NTC sensor connected) |
| Connections | 2 pcs mini-DIN Micro USB TCI (Testo Communication Interface) |
| Log interval | 5 s ... 24 h (LAN Ethernet communication) 1 min ... 24 h (testo UltraRange radio communication or WLAN) |
| Channels | 2 |
| Internal storage (per channel) | my. 128,000 measurement values |
| Data transfer | 5 s ... 24 h (Ethernet communication) 1 min ... 24 h (testo UltraRange or WLAN) |
| Wall mount | Included |
NTC probes
-

Air probe, short (TUC)
1 550 SKU 0572 2162Digital probe without cable for measuring air temperature
- Sensor type: NTC
- Measuring range: -30 … +50 °C
- Accuracy: ±0.5 °C (-30 … +50 °C)
- Probe length: 120 mm
- Diameter: 20 mm
-

Surface probe for pipes, max. Ø 75 mm (TUC)
1 295 SKU 0615 4611Probe with Velcro strap for measurement on pipes with max. diameter 75 mm
- Sensor type: NTC
- Measuring range: -40 to +70 °C
- Accuracy: ±0.2 °C (-25 to +70 °C)
- Sensor length: 300 mm
- Diameter: 30 mm
-

Penetration probe, stainless steel Teflon-insulated cable (DIN)
2 135 SKU 0613 3311Waterproof probe, IP67, heat-resistant probe cable Tmax +200 °C. Suitable for food and environments with strong chemicals.
- Sensor type: NTC
- Measuring range: -50 … +150 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 125 mm
- Diameter: 4 mm
-

Penetration probe, stainless steel with PUR cable (DIN)
1 710 SKU 0613 2211Waterproof probes, IP 65, well-suited for food
- Sensor type: NTC
- Measuring range: -50 … +150 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 125 mm
- Diameter: 4 mm
-

Plug-in probe, robust with handle (DIN)
1 145 SKU 0613 1212Waterproof, versatile penetration probe with handle and robust construction
- Sensor type: NTC
- Measuring range: -50 … +150 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 115 mm
- Diameter: 5 mm
-

Insertion probe with special handle (DIN)
1 620 SKU 0613 2411Robust food probe with special handle, reinforced PUR cable
- Sensor type: NTC
- Measurement range: -50 … +125 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 115 mm
- Diameter: 5 mm
-

Penetration probe, corkscrew (DIN)
2 485 SKU 0613 3211Robust probe for frozen foods with a corkscrew tip
- Sensor type: NTC
- Measurement range: -50 … +125 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 110 mm
- Diameter: 8 mm
-

Insertion probe, flat cable (DIN)
995 SKU 0572 1001Probes, IP54, with flat Teflon-insulated cable Tmax +125 °C. The cable can be routed through narrow openings such as gaps in doors or refrigerator seals.
- Sensor type: NTC
- Measuring range: -40 … +125 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 60 mm
- Diameter: 3.6 mm
-

Immersion probe, 1.5 m cable (DIN)
930 SKU 0628 0006Waterproof probe, IP 67, suitable for long-term measurement indoors, outdoors, and in refrigerators and freezers
- Sensor type: NTC
- Measurement range: -35 … +80 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 40 mm
- Diameter: 3 mm
-

Immersion probe with 2.4 m cable (DIN)
615 SKU 0628 7503Waterproof probe, IP 65, with aluminum-protected measuring tip. Suitable for long-term measurement.
- Sensor type: NTC
- Measurement range: -30 … +90 °C
- Accuracy: ±0.2 °C (0 ... +70 °C)
- Sensor length: 40 mm
- Diameter: 6 mm
-

Immersion probe with 6 m cable (DIN)
1 060 SKU 0610 1725Waterproof probe, IP67, suitable for long-term measurement indoors, outdoors, and in cold rooms and freezers.
- Sensor type: NTC
- Measurement range: -35 … +80 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 40 mm
- Diameter: 3 mm
-

Immersion probe short 35 mm (DIN)
505 SKU 0628 7510Short probe, IP 54. Suitable for measuring air temperature but can also be used in liquids and viscous media.
- Sensor type: NTC
- Measuring range: -20 … +70 °C
- Accuracy: ±0.2 °C (-20 ... +70 °C)
- Sensor length: 35 mm
- Diameter: 3 mm
-

Air probe, robust with handle (DIN)
1 160 SKU 0613 1712Rugged air probe with handle. Exposed sensor for fast response times.
- Sensor type: NTC
- Measuring range: -50 … +150 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 115 mm
- Diameter: 5 mm
-

Surface probe with rigid probe tip (DIN)
1 300 SKU 0613 1912Waterproof probe with flat measuring tip for measuring on flat surfaces
- Sensor type: NTC
- Measuring range: -50 … +150 °C
- Accuracy: ±0.2 °C (-25 ... +75 °C)
- Sensor length: 115 mm
- Diameter: 5 mm
-

Surface sensor for pipes Ø max 75 mm (DIN)
1 235 SKU 0613 4611Probe with Velcro strap for measurement on pipes with max. diameter 75 mm
- Sensor type: NTC
- Mätområde: -50 … +105 °C
- Accuracy: ±0.2 °C (-25 to +70 °C)
- Sensor length: 300 mm
- Diameter: 30 mm
-

Surface sensor for pipes Ø 6–35 mm (DIN)
665 SKU 0613 5505Probe for measurement on pipes with diameter 6–35 mm. The clamp enables quick and easy mounting.
- Sensor type: NTC
- Measuring range: -40 … +125 °C
- Accuracy: ±1 °C (-20 … +85 °C)
-

Surface sensor for wall surfaces (DIN)
845 SKU 0628 7507Surface temperature sensor that screws onto the wall.
- Sensor type: NTC
- Measuring range: -50 … +80 °C
- Accuracy: ±0.2 °C (0 ... +70 °C)
- Sensor length: 40 mm
- Width: 10 mm
Pt100 probes
-

Plug-in probe, robust with handle (DIN)
1 300 SKU 0609 1273Waterproof, versatile penetration probe with handle and robust construction
- Sensor type: Pt100
- Measuring range: -50 … +400 °C
- Accuracy: Class A
- Sensor length: 114 mm
- Diameter: 5 mm
-

Insticksgivare, rostfritt stål PUR-kabel (DIN)
2 160 SKU 0609 2272Waterproof probes, IP 65, well-suited for food
- Sensor type: Pt100
- Measuring range: -50 … +400 °C
- Accuracy: Class A
- Sensor length: 125 mm
- Diameter: 4 mm
-

Penetration probe, flat cable -85 °C (DIN)
1 875 SKU 0572 7001Probe with flat Teflon-insulated cable for low-temperature applications. Can be passed through gaps in doors or refrigerator seals.
- Sensor type: Pt100
- Measuring range: -85 … +150 °C
- Accuracy: Class A
- Sensor length: 60 mm
- Diameter: 4 mm
-

Glass-coated immersion probe (DIN)
1 730 SKU 0609 7072Probe with a glass protective sheath, resistant to corrosive substances. The glass cover is removable.
- Sensor type: Pt100
- Measuring range: -50 … +400 °C
- Accuracy: Class A
- Probe length: 200 mm
- Diameter: 6 mm
-

Air probe, robust with handle (DIN)
1 405 SKU 0609 1773Affordable robust air sensor.
- Sensor type: Pt100
- Measuring range: -50 … +400 °C
- Accuracy: Class A
- Sensor length: 114 mm
- Diameter: 4 mm
-

Surface probe with rigid probe tip (DIN)
1 750 SKU 0609 1973Robust waterproof probe with flat measuring tip for measurement on flat surfaces
- Sensor type: Pt100
- Measuring range: -50 … +400 °C
- Noggrannhet: Klass B
- Sensor length: 114 mm
- Diameter: 5 mm
-

Surface sensor for pipes Ø 6–120 mm (DIN)
1 725 SKU 0609 5602Velcro sensor for measuring on pipes with a maximum diameter of 120 mm
- Sensor type: Pt100
- Measuring range: -50 … +120 °C
- Accuracy: Class B
- Probe length: 430 mm
- Bredd: 20 mm
-

testo Saveris CFR Part 11
SKU 0572 0182Validatable CFR software for the remote measurement system testo Saveris
- Management of alarms incl. managing escalations
- Management of calibration
- Enhanced analysis capabilities without data export to CSV file (optional) - Individual reporting based on current rules and user preferences.
- Traceability and the ERES (Electronic Records / Electronic Signatures) principle, which is based on legal requirements in accordance with 21 CFR Part 11 and EU Annex 11 of the GMP Regulation.
- Reliable user management based on different Windows user groups with their respective entries in Windows Active Directory.
- Simple, intuitive and platform-independent user interface
- Minimal investment in training, course materials and SOP documents
- Geographically hierarchical structure allowing to zoom in on complex systems with a large number of measurement sites
- Reliable user management based on customer content in Windows Active Directory
- Access management and permissions for alarm acknowledgment
- Customization of the system by uploading your own floor plans and logos.
Product Added to Quote Successfully.Send a request
Visa förfrågan -

Magnetic attachment for wall holders
270 SKU 0554 2001Magnetic bracket compatible with wall holders for the previous and new generation of data loggers in the testo Saveris Cloud series and the testo 150 series loggers.
-

LAN/PoE module
SKU 0554 9330LAN communication module with PoE for testo 150 loggers. The module component is mounted on a testo 150 logger for communication via fixed network (LAN) in the measurement system testo Saveris. Also supports PoE, i.e. power supply via the network cable.
- Transmission interval: 5 sec ... 24 hours
- Connection: LAN
- Protection class: IP30 (when connected to a testo 150 logger)
Product Added to Quote Successfully.Send a request
Visa förfrågan -

WLAN module
SKU 0554 9320 01WLAN communication module for testo 150 loggers. Module component that is mounted on a testo 150 logger for communication via wireless network (WLAN) in the measurement system testo Saveris.
- Radio frequency: 2.4 GHz
- Transmission interval: 1 min ... 24 hours
- Protection class: IP67 (when connected to a testo 150 logger)
Product Added to Quote Successfully.Send a request
Visa förfrågan -

testo UltraRange module
SKU 0554 9311 01Modular component mounted on a testo 150 logger for communication via radio in the testo Saveris measuring system.
- Radio frequency: 868 MHz
- Transmission interval: 1 min ... 24 hours
- Protection class: IP67 (when connected to a testo 150 logger)
Product Added to Quote Successfully.Send a request
Visa förfrågan -

Power supplies & cable
766 SKU 0572 5004Power supply for the testo Saveris measuring system. Power supply & USB cable to data loggers, base station and gateway.