testo 6383 – with hygienic front panel
Installed in cleanroom applications and various hygiene zones in e.g. hospitals.
- Hygienic front panel for reading in clean zone
- Display with alarm indication (optional)
- No zero point drift thanks to automatic zero adjustment function
Recessed mounting in wall panel
Transmitter for hygienic wall mounting
testo 6383 is specially designed to be installed in cleanroom applications and various hygiene zones in hospitals. It is one of the most accurate instruments and there are 10 different measurement ranges to choose from when ordering, from 0 ... 10 Pa up to -10 ... +10 hPa. Thanks to the automatic zeroing, there is no zero point drift. This transmitter also has no temperature dependency as zeroing is done at the process temperature. It also has a very good overpressure protection of 140% of the measuring range, as well as alarm management with adjustable response time and alarm acknowledgement. Optional temperature and relative humidity sensors can also be connected to the transmitter.
The transmitter can deliver data directly to an FMS system.
- Hygienic front panel for reading in clean zone
- Display with alarm indication (optional)
- Zero in zero point operation thanks to automatic zero adjustment function
- Effective overpressure protection
- High long-term stability and repeatability
- Can also be supplied with other print areas, call for more information.
Contact us for prices and more information.
| Measurement range | 0 ...10 Pa 0 ...50 Pa 0 ...100 Pa 0 ...500 Pa 0 ...10 hPa -10 ...+10 Pa -50 ...+50 Pa -100 ...+100 Pa -500 ...+500 Pa -10 ...+10 hPa |
| Measurement uncertainty | ±0.3% of the final value of the measuring range ±0.3 Pa Zero drift: 0% (thanks to regular zero adjustment) |
| Units of measurement | Differential pressure in Pa, hPa, kPa, mbar, bar, mmH2O, kg/cm2, PSI, inch HG, inch H2O |
| Sensor | “Piezoresistive sensor |
| Automatic zero point adjustment | Via solenoid valve Adjustable interval: 15 sec, 30 sec, 1 min, 5 min, 10 min |
| Overload | Depending on the measurement range, see PDF. |
| GENERAL TECHNICAL DATA | |
| Material | stainless steel front, plastic instrument housing |
| Size | Without moisture/temperature: 246 x 161 x 47 mm With humidity/temperature: 396 x 161 x 78 mm |
| Weight | Version without moisture: 0.9 kg Version with integrated humidity sensor: 1.35 kg Version prepared for external humidity sensor: 1.26 kg |
| DISPLAY | |
| Display | Option: 3-line LCD with multilingual function menu |
| Resolution | Depending on the measurement range and measurement quantity, see PDF |
| OTHER | |
| Protection class | IP 65 |
| Connection nipple | Ø 6 mm --> suitable hoses 4 mm + 4.8 mm |